EATON 118561

dil-swd-32-002

$198.24 $396.48 -50%
9 pcs. with 1 to 3 days delivery to United States

Specifications

Mounting Position as dilm7 to dilm38
Width 45 mm
Weight 37g
burst impulse 1 kv, smartwire-dt cable, according to iec/en 61131-2, level 3
1 kv, signal cable, according to iec/en 61131-2, level 3
time delay at signal exchange - min 10 ms
supply voltage at ac, 50 hz - max 0 vac
supply voltage at ac, 50 hz - min 0 vac
number of hw-interfaces (other) 1
connection type swd: plug, 8-pole
push in terminals, auxiliary contact
external device plug swd4-8sf2-5, smartwire-dt
10.2.3.2 verification of resistance of insulating materials to normal heat meets the product standard's requirements.
number of outputs (digital) 1
air discharge 8 kv, according to iec 61131-2, level 3, esd
height of fall (iec/en 60068-2-32) - max .3 m
drop and topple 50 mm drop height, drop to iec/en 60068-2-31
heat dissipation per pole, current-dependent pvid 0 w
10.13 mechanical function the device meets the requirements, provided the information in the instruction leaflet (il) is observed.
permitted voltage at output - min 20.4 v
supply voltage at dc - max 15 vdc
Cable length ≤ 2.8 m, connection auxiliary contact
10.9.3 impulse withstand voltage is the panel builder's responsibility.
static heat dissipation, non-current-dependent pvs .8 w
permitted voltage at output - max 28.8 v
contact discharge 4 kv, according to iec/en 61131-2, level 2, esd
10.2.5 lifting does not apply, since the entire switchgear needs to be evaluated.
number of auxiliary contacts 2
pick-up current 125 ma (for dilm 7-9)
188 ma (for dilm 12-15)
500 ma (for dilm 17-38)
Environmental conditions condensation: prevent with appropriate measures
10.2.4 resistance to ultra-violet (uv) radiation meets the product standard's requirements.
10.2.2 corrosion resistance meets the product standard's requirements.
functions display of contactor switching position, status of the digital inputs 1 and 2, 1-0-a switch position
for connecting the contactors to smartwire-dt
contactor actuation
Pollution degree 2
Degree of protection ip20
10.9.2 power-frequency electric strength is the panel builder's responsibility.
output current 0.5 a
addressing address set automatically
heat dissipation capacity pdiss 0 w
radio interference class class a (en 55011)
product category smartwire-dt slave
voltage type dc
10.3 degree of protection of assemblies does not apply, since the entire switchgear needs to be evaluated.
10.6 incorporation of switching devices and components does not apply, since the entire switchgear needs to be evaluated.
ambient operating temperature - min -25 °c
permitted voltage at input - min 15 v
input current at signal 1 3 ma
explosion safety category for gas none
constant amplitude 3,5 mm, 5 - 8.4 hz, according to iec/en 61131-2, vibrations
ambient storage temperature - min 30 °c
led indicator status indication of smartwire-dt network: green and orange led
rated operational voltage 15 v dc (auxiliary contact)
rated operational current for specified heat dissipation (in) 0 a
certifications ul 508
iec/en 60947
ul
en 50178
ce
csa file no.: 2324643
csa class no.: 3211-07
ul file no.: e29184
iec/en 61131-2
ul category control no.: nkcr
csa-c22.2 no. 14-05
iec/en 60947-4-1
csa
product width 45 mm
product length/depth 72 mm
explosion safety category for dust none
10.10 temperature rise the panel builder is responsible for the temperature rise calculation. eaton will provide heat dissipation data for the devices.
10.7 internal electrical circuits and connections is the panel builder's responsibility.
relative humidity 5 - 95 % (non-condensing, iec/en 60068-2-30)
time delay at signal exchange - max 84 ms
10.2.3.3 resist. of insul. mat. to abnormal heat/fire by internal elect. effects meets the product standard's requirements.
power consumption 3 w for dilm 7-9 (pick-up power)
4.5 w for dilm 12-15 (sealing power)
12 w for dilm 17-38 (pick-up power)
3 w for dilm 7-9 (sealing power)
4.5 w for dilm 12-15 (pick-up power)
0.5 w for dilm 17-38 (sealing power)
operating mode address allocation via rotary switch
control mode
equipment heat dissipation, current-dependent pvid 0 w
supply voltage at ac, 60 hz - min 0 vac
safety performance level (en iso 13849-1) none
10.9.4 testing of enclosures made of insulating material is the panel builder's responsibility.
electric connection type spring clamp connection
Mounting position as dilm7 to dilm38
10.5 protection against electric shock does not apply, since the entire switchgear needs to be evaluated.
number of inputs (digital) 2
sealing current 188 ma, smartwire-dt network for dilm 12-15
21 ma, smartwire-dt network for dilm 17-38
125 ma, smartwire-dt network for dilm 7-9
connection to smartwire-dt yes
supply voltage at dc - min 15 vdc
10.8 connections for external conductors is the panel builder's responsibility.
10.12 electromagnetic compatibility is the panel builder's responsibility. the specifications for the switchgear must be observed.
Shock resistance 15 g, mechanical, according to iec/en 60068-2-27, half-sinusoidal shock 11 ms, 9 impacts
Current consumption 40 ma, smartwire-dt network
10.2.7 inscriptions meets the product standard's requirements.
data transmission type none
Type swd contactor modules
sil (iec 61508) none
ambient storage temperature - max 70 °c
Overvoltage category ii
Protocol other bus systems
electromagnetic fields 3 v/m at 1.4 - 2 ghz (according to iec/en 61131-2:2008)
10 v/m at 80 - 1000 mhz (according to iec/en 61131-2:2008)
1 v/m at 2.0 - 2.7 ghz (according to iec/en 61131-2:2008)
constant acceleration 1 g, 8.4 - 150 hz, according to iec/en 61131-2, vibrations
terminal capacity 0.2 - 1.5 mm² (24 - 16 awg), solid
0.25 - 1.5 mm², flexible with ferrule
potential isolation connection auxiliary contact: no
category (en 954-1) 1
permitted voltage at input - max 15 v
10.2.6 mechanical impact does not apply, since the entire switchgear needs to be evaluated.
supply voltage at ac, 60 hz - max 0 vac
station smartwire-dt slave, smartwire-dt network
Features fieldbus connection over separate bus coupler possible
ambient operating temperature - max 60 °c
system accessory yes
fitted with: own supply
10.2.3.1 verification of thermal stability of enclosures meets the product standard's requirements.
10.4 clearances and creepage distances meets the product standard's requirements.
10.11 short-circuit rating is the panel builder's responsibility. the specifications for the switchgear must be observed.
radiated rfi 10 v (iec/en 61131-2:2008, level 3)
Product weight .037 kg
product height 38 mm
ean 4015081168316
$198.24
Stock 9 pcs.
Part number 118561
Manufacturer EATON
Quantity Unit Price
1 - 4 $198.24
5+ $194.28
  • Open Registration
    Create your account instantly
  • Support 24/7
    Ask us anytime
  • 100% Safety
    Only secure payments: bank transfer, credit card and PayPal
  • Volume Discounts
    Optimize your supplies