burst impulse | 1 kv, smartwire-dt cable, according to iec/en 61131-2, level 3 1 kv, signal cable, according to iec/en 61131-2, level 3 |
||
time delay at signal exchange - min | 10 ms | ||
supply voltage at ac, 50 hz - max | 0 vac | ||
supply voltage at ac, 50 hz - min | 0 vac | ||
number of hw-interfaces (other) | 1 | ||
connection type | swd: plug, 8-pole push in terminals, auxiliary contact external device plug swd4-8sf2-5, smartwire-dt |
||
10.2.3.2 verification of resistance of insulating materials to normal heat | meets the product standard's requirements. | ||
number of outputs (digital) | 1 | ||
air discharge | 8 kv, according to iec 61131-2, level 3, esd | ||
height of fall (iec/en 60068-2-32) - max | .3 m | ||
drop and topple | 50 mm drop height, drop to iec/en 60068-2-31 | ||
heat dissipation per pole, current-dependent pvid | 0 w | ||
10.13 mechanical function | the device meets the requirements, provided the information in the instruction leaflet (il) is observed. | ||
permitted voltage at output - min | 20.4 v | ||
supply voltage at dc - max | 15 vdc | ||
Cable length | ≤ 2.8 m, connection auxiliary contact | ||
10.9.3 impulse withstand voltage | is the panel builder's responsibility. | ||
static heat dissipation, non-current-dependent pvs | .8 w | ||
permitted voltage at output - max | 28.8 v | ||
contact discharge | 4 kv, according to iec/en 61131-2, level 2, esd | ||
10.2.5 lifting | does not apply, since the entire switchgear needs to be evaluated. | ||
number of auxiliary contacts | 2 | ||
pick-up current | 125 ma (for dilm 7-9) 188 ma (for dilm 12-15) 500 ma (for dilm 17-38) |
||
Environmental conditions | condensation: prevent with appropriate measures | ||
10.2.4 resistance to ultra-violet (uv) radiation | meets the product standard's requirements. | ||
10.2.2 corrosion resistance | meets the product standard's requirements. | ||
functions | display of contactor switching position, status of the digital inputs 1 and 2, 1-0-a switch position for connecting the contactors to smartwire-dt contactor actuation |
||
Pollution degree | 2 | ||
Degree of protection | ip20 | ||
10.9.2 power-frequency electric strength | is the panel builder's responsibility. | ||
output current | 0.5 a | ||
addressing | address set automatically | ||
heat dissipation capacity pdiss | 0 w | ||
radio interference class | class a (en 55011) | ||
product category | smartwire-dt slave | ||
voltage type | dc | ||
10.3 degree of protection of assemblies | does not apply, since the entire switchgear needs to be evaluated. | ||
10.6 incorporation of switching devices and components | does not apply, since the entire switchgear needs to be evaluated. | ||
ambient operating temperature - min | -25 °c | ||
permitted voltage at input - min | 15 v | ||
input current at signal 1 | 3 ma | ||
explosion safety category for gas | none | ||
constant amplitude | 3,5 mm, 5 - 8.4 hz, according to iec/en 61131-2, vibrations | ||
ambient storage temperature - min | 30 °c | ||
led indicator | status indication of smartwire-dt network: green and orange led | ||
rated operational voltage | 15 v dc (auxiliary contact) | ||
rated operational current for specified heat dissipation (in) | 0 a | ||
certifications | ul 508 iec/en 60947 ul en 50178 ce csa file no.: 2324643 csa class no.: 3211-07 ul file no.: e29184 iec/en 61131-2 ul category control no.: nkcr csa-c22.2 no. 14-05 iec/en 60947-4-1 csa |
||
product width | 45 mm | ||
product length/depth | 72 mm |
explosion safety category for dust | none | ||
10.10 temperature rise | the panel builder is responsible for the temperature rise calculation. eaton will provide heat dissipation data for the devices. | ||
10.7 internal electrical circuits and connections | is the panel builder's responsibility. | ||
relative humidity | 5 - 95 % (non-condensing, iec/en 60068-2-30) | ||
time delay at signal exchange - max | 84 ms | ||
10.2.3.3 resist. of insul. mat. to abnormal heat/fire by internal elect. effects | meets the product standard's requirements. | ||
power consumption | 3 w for dilm 7-9 (pick-up power) 4.5 w for dilm 12-15 (sealing power) 12 w for dilm 17-38 (pick-up power) 3 w for dilm 7-9 (sealing power) 4.5 w for dilm 12-15 (pick-up power) 0.5 w for dilm 17-38 (sealing power) |
||
operating mode | address allocation via rotary switch control mode |
||
equipment heat dissipation, current-dependent pvid | 0 w | ||
supply voltage at ac, 60 hz - min | 0 vac | ||
safety performance level (en iso 13849-1) | none | ||
10.9.4 testing of enclosures made of insulating material | is the panel builder's responsibility. | ||
electric connection type | spring clamp connection | ||
Mounting position | as dilm7 to dilm38 | ||
10.5 protection against electric shock | does not apply, since the entire switchgear needs to be evaluated. | ||
number of inputs (digital) | 2 | ||
sealing current | 188 ma, smartwire-dt network for dilm 12-15 21 ma, smartwire-dt network for dilm 17-38 125 ma, smartwire-dt network for dilm 7-9 |
||
connection to smartwire-dt | yes | ||
supply voltage at dc - min | 15 vdc | ||
10.8 connections for external conductors | is the panel builder's responsibility. | ||
10.12 electromagnetic compatibility | is the panel builder's responsibility. the specifications for the switchgear must be observed. | ||
Shock resistance | 15 g, mechanical, according to iec/en 60068-2-27, half-sinusoidal shock 11 ms, 9 impacts | ||
Current consumption | 40 ma, smartwire-dt network | ||
10.2.7 inscriptions | meets the product standard's requirements. | ||
data transmission type | none | ||
Type | swd contactor modules | ||
sil (iec 61508) | none | ||
ambient storage temperature - max | 70 °c | ||
Overvoltage category | ii | ||
Protocol | other bus systems | ||
electromagnetic fields | 3 v/m at 1.4 - 2 ghz (according to iec/en 61131-2:2008) 10 v/m at 80 - 1000 mhz (according to iec/en 61131-2:2008) 1 v/m at 2.0 - 2.7 ghz (according to iec/en 61131-2:2008) |
||
constant acceleration | 1 g, 8.4 - 150 hz, according to iec/en 61131-2, vibrations | ||
terminal capacity | 0.2 - 1.5 mm² (24 - 16 awg), solid 0.25 - 1.5 mm², flexible with ferrule |
||
potential isolation | connection auxiliary contact: no | ||
category (en 954-1) | 1 | ||
permitted voltage at input - max | 15 v | ||
10.2.6 mechanical impact | does not apply, since the entire switchgear needs to be evaluated. | ||
supply voltage at ac, 60 hz - max | 0 vac | ||
station | smartwire-dt slave, smartwire-dt network | ||
Features | fieldbus connection over separate bus coupler possible | ||
ambient operating temperature - max | 60 °c | ||
system accessory | yes | ||
fitted with: | own supply | ||
10.2.3.1 verification of thermal stability of enclosures | meets the product standard's requirements. | ||
10.4 clearances and creepage distances | meets the product standard's requirements. | ||
10.11 short-circuit rating | is the panel builder's responsibility. the specifications for the switchgear must be observed. | ||
radiated rfi | 10 v (iec/en 61131-2:2008, level 3) | ||
Product weight | .037 kg | ||
product height | 38 mm | ||
ean | 4015081168316 |
Stock | 9 pcs. |
---|---|
Part number | 118561 |
Manufacturer | EATON |
Quantity | Unit Price |
---|---|
1 - 4 | $198.24 |
5+ | $194.28 |