rated insulation voltage (ui) | 400 v | ||
Shock resistance | 25 g, standard-action contact, mechanical, half-sinusoidal shock 20 ms | ||
rated operational current (ie) at dc-13, 110 v | .6 a | ||
number of contacts (normally open contacts) | 2 | ||
10.2.4 resistance to ultra-violet (uv) radiation | meets the product standard's requirements. | ||
actuating force at beginning/end of stroke | 1.0 n/8.0 n | ||
Type | position switch | ||
enclosure material | insulated material plastic |
||
10.10 temperature rise | the panel builder is responsible for the temperature rise calculation. eaton will provide heat dissipation data for the devices. | ||
rated impulse withstand voltage (uimp) | 4000 v ac | ||
Pollution degree | 3 | ||
Degree of protection | ip66/ip67 nema other |
||
control circuit reliability | 1 failure per 10,000,000 switching operations (statistically determined, at 24 v dc/5 ma) 1 failure per 5,000,000 switching operations (statistically determined, at 5 v dc/1 ma) |
||
switch function type | slow-action switch | ||
operating speed | max. 1/0.5 m/s (with din cam, mechanical actuation) for angle of actuation α = 0°/30° |
||
10.2.3.3 resist. of insul. mat. to abnormal heat/fire by internal elect. effects | meets the product standard's requirements. | ||
terminal capacity (solid) | 1 x (0.5 - 2.5) mm² | ||
equipment heat dissipation, current-dependent pvid | 0 w | ||
product category | rounded plunger | ||
rated operational current (ie) at ac-15, 380 v, 400 v, 415 v | 4 a | ||
width sensor | 31 mm | ||
10.9.4 testing of enclosures made of insulating material | is the panel builder's responsibility. | ||
10.13 mechanical function | the device meets the requirements, provided the information in the instruction leaflet (il) is observed. | ||
rated operational current (ie) at ac-15, 220 v, 230 v, 240 v | 4 a | ||
10.5 protection against electric shock | does not apply, since the entire switchgear needs to be evaluated. | ||
ambient operating temperature - min | -25 °c | ||
static heat dissipation, non-current-dependent pvs | 0 w | ||
rated operational current (ie) at ac-15, 24 v | 6 a | ||
ambient operating temperature - max | 70 °c | ||
enclosure type | cuboid | ||
explosion safety category for gas | none | ||
actuator type | plunger | ||
10.8 connections for external conductors | is the panel builder's responsibility. | ||
10.2.3.1 verification of thermal stability of enclosures | meets the product standard's requirements. | ||
10.12 electromagnetic compatibility | is the panel builder's responsibility. the specifications for the switchgear must be observed. | ||
diameter sensor | 0 mm | ||
temperature resistance | 100 °c, contact temperature of roller head | ||
10.11 short-circuit rating | is the panel builder's responsibility. the specifications for the switchgear must be observed. | ||
Repetition accuracy | 0.15 mm (contacts/switching capacity) | ||
certifications | ul 508 csa csa file no.: 012528 ul file no.: e29184 csa class no.: 3211-03 ul category control no.: nkcr iec/en 60947-5 iec/en 60947 ul csa-c22.2 no. 14 ce |
||
product width | 31 mm | ||
product length/depth | 33.5 mm |
rated operational current (ie) at dc-13, 24 v | 3 a | ||
lifespan | 8,000,000 mechanical operations | ||
short-circuit protection rating | max. 6 a gg/gl, fuse, contacts | ||
10.2.7 inscriptions | meets the product standard's requirements. | ||
supply frequency | max. 400 hz, contacts | ||
10.2.2 corrosion resistance | meets the product standard's requirements. | ||
explosion safety category for dust | none | ||
rated operational current (ie) at ac-15, 125 v | 4 a | ||
actuator alignment | roller cam straight | ||
10.7 internal electrical circuits and connections | is the panel builder's responsibility. | ||
enclosure material finishing | other | ||
Overvoltage category | iii | ||
10.9.2 power-frequency electric strength | is the panel builder's responsibility. | ||
rated operational current (ie) at dc-13, 220 v, 230 v | .3 a | ||
connection type | cage clamp | ||
10.2.3.2 verification of resistance of insulating materials to normal heat | meets the product standard's requirements. | ||
heat dissipation capacity pdiss | 0 w | ||
action | 2020122120328-mechanical limit switches.xlsm-data | ||
operating frequency | 6000 operations/h | ||
heat dissipation per pole, current-dependent pvid | .17 w | ||
10.3 degree of protection of assemblies | does not apply, since the entire switchgear needs to be evaluated. | ||
10.2.6 mechanical impact | does not apply, since the entire switchgear needs to be evaluated. | ||
electric connection type | cable entry metrical | ||
Mounting position | as required | ||
10.6 incorporation of switching devices and components | does not apply, since the entire switchgear needs to be evaluated. | ||
10.9.3 impulse withstand voltage | is the panel builder's responsibility. | ||
Features | expandable | ||
climatic proofing | damp heat, constant, to iec 60068-2-78 damp heat, cyclic, to iec 60068-2-30 |
||
actuating torque of rotary drives | .2 nm | ||
sensor length | 33.5 mm | ||
sensor height | 61 mm | ||
rated conditional short-circuit current (iq) | 1 ka | ||
interface type | none | ||
10.2.5 lifting | does not apply, since the entire switchgear needs to be evaluated. | ||
10.4 clearances and creepage distances | meets the product standard's requirements. | ||
rated operational current (ie) at dc-13, 125 v | .3 a | ||
enclosure color | yellow cover | ||
terminal capacity (flexible with ferrule) | 1 x (0.5 - 1.5) mm² | ||
rated operational current for specified heat dissipation (in) | 6 a | ||
Product weight | .05 kg | ||
product height | 76.5 mm | ||
ean | 4015081164516 |