rated insulation voltage (ui) | 250 v | ||
suitable for number of built-in signal lights | 1 | ||
10.2.4 resistance to ultra-violet (uv) radiation | please enquire | ||
Type | indicator lights | ||
Size | front diameter: 29.7 mm | ||
rated impulse withstand voltage (uimp) | 4000 v ac | ||
Pollution degree | 3 | ||
Degree of protection | nema 4x, 13 | ||
10.9.2 power-frequency electric strength | is the panel builder's responsibility. | ||
10.2.3.3 resist. of insul. mat. to abnormal heat/fire by internal elect. effects | meets the product standard's requirements. | ||
width opening | 0 mm | ||
equipment heat dissipation, current-dependent pvid | 0 w | ||
product category | rmq-titan | ||
10.3 degree of protection of assemblies | does not apply, since the entire switchgear needs to be evaluated. | ||
10.2.6 mechanical impact | does not apply, since the entire switchgear needs to be evaluated. | ||
Mounting position | as required | ||
10.6 incorporation of switching devices and components | does not apply, since the entire switchgear needs to be evaluated. | ||
10.9.3 impulse withstand voltage | is the panel builder's responsibility. | ||
connection to smartwire-dt | with swd-rmq connections yes |
||
bezel color | chrome | ||
lens color | green | ||
force for positive opening - min | 0 n | ||
fitted with: | front ring | ||
Design | flush | ||
10.12 electromagnetic compatibility | is the panel builder's responsibility. the specifications for the switchgear must be observed. | ||
opening diameter | 22.5 mm | ||
rated operational current for specified heat dissipation (in) | 0 a | ||
compliances | ce marked | ||
product width | 30 mm | ||
product length/depth | 30 mm |
Shock resistance | 30 g, mechanical, according to iec/en 60068-2-27, sinusoidal shock 11 ms mechanical, according to iec/en 60068-2-27 |
||
10.2.7 inscriptions | meets the product standard's requirements. | ||
10.2.2 corrosion resistance | meets the product standard's requirements. | ||
lens type | flat round |
||
10.10 temperature rise | not applicable. | ||
10.7 internal electrical circuits and connections | is the panel builder's responsibility. | ||
opening height | 22.5 mm | ||
Overvoltage category | iii | ||
bezel material | other | ||
10.2.3.2 verification of resistance of insulating materials to normal heat | meets the product standard's requirements. | ||
heat dissipation capacity pdiss | 0 w | ||
terminal capacity | 0.5 - 1.5 mm², solid 0.5 - 1.5 mm², stranded |
||
heat dissipation per pole, current-dependent pvid | 0 w | ||
10.9.4 testing of enclosures made of insulating material | is the panel builder's responsibility. | ||
10.13 mechanical function | the device meets the requirements, provided the information in the instruction leaflet (il) is observed. | ||
10.5 protection against electric shock | does not apply, since the entire switchgear needs to be evaluated. | ||
ambient operating temperature - min | -25 °c | ||
static heat dissipation, non-current-dependent pvs | 0 w | ||
climatic proofing | damp heat, constant, to iec 60068-2-78 damp heat, cyclic, to iec 60068-2-30 |
||
ambient operating temperature - max | 70 °c | ||
10.8 connections for external conductors | is the panel builder's responsibility. | ||
degree of protection (front side) | ip67/ip69k | ||
10.2.3.1 verification of thermal stability of enclosures | meets the product standard's requirements. | ||
10.2.5 lifting | does not apply, since the entire switchgear needs to be evaluated. | ||
10.4 clearances and creepage distances | meets the product standard's requirements. | ||
10.11 short-circuit rating | is the panel builder's responsibility. the specifications for the switchgear must be observed. | ||
certifications | en 60947-5 ul 508 csa std. c22.2 no. 14-05 csa std. c22.2 no. 94-91 iec 60947-5 vde ce csa-c22.2 no. 14-05 ul category control no.: nkcr ul file no.: e29184 csa csa file no.: 012528 iec/en 60947 ul csa class no.: 3211-03 vde 0660 csa-c22.2 no. 94-91 iec/en 60947-5 |
||
Product weight | .007 kg | ||
product height | 30 mm | ||
ean | 4015082167738 |