Eaton 003772

t0-11-15296/e

$257.82 12 pcs. with 1 to 3 days delivery to United States

Specifications

Width Weight Mounting Position
48 mm 339g as required
ean 4015080037729
rated operational current (ie) star-delta at ac-3, 500 v 15.6 a
terminal capacity (solid/stranded) 2 x (1 - 2.5) mm²
1 x (1 - 2.5) mm²
assigned motor power at 230/240 v, 60 hz, 1-phase 1.5 hp
number of contacts in series at dc-23a, 120 v 3
10.10 temperature rise the panel builder is responsible for the temperature rise calculation. eaton will provide heat dissipation data for the devices.
rated short-time withstand current (icw) 320 a, contacts, 1 second
number of contacts in series at dc-23a, 60 v 3
number of contacts 22
10.2.3.3 resist. of insul. mat. to abnormal heat/fire by internal elect. effects meets the product standard's requirements.
10.2.3.2 verification of resistance of insulating materials to normal heat meets the product standard's requirements.
rated operational current (ie) at dc-1, load-break switches l/r = 1 ms 10 a
front shield size 48x48 mm
suitable for branch circuits, suitable as motor disconnect, (ul/csa)
front mounting
equipment heat dissipation, current-dependent pvid 0 w
rated operational power star-delta at 500 v, 50 hz 7.5 kw
rated operational current (ie) star-delta at ac-3, 400 v 20 a
10.9.4 testing of enclosures made of insulating material is the panel builder's responsibility.
rated operational power at ac-23a, 690 v, 50 hz 5.5 kw
actuator function maintained
without 0 (off) position
Mounting position as required
10.5 protection against electric shock does not apply, since the entire switchgear needs to be evaluated.
static heat dissipation, non-current-dependent pvs 0 w
device construction built-in device
rated operational power at ac-3, 415 v, 50 hz 5.5 kw
load rating 1.3 x iₑ (with intermittent operation class 12, 60 % duty factor)
2 x iₑ (with intermittent operation class 12, 25 % duty factor)
1.6 x iₑ (with intermittent operation class 12, 40 % duty factor)
screw size m3.5, terminal screw
rated operational current (ie) star-delta at ac-3, 230 v 20 a
ambient operating temperature (enclosed) - max 40 °c
10.12 electromagnetic compatibility is the panel builder's responsibility. the specifications for the switchgear must be observed.
rated operational current (ie) at dc-23a, 60 v 10 a
rated operational power at ac-23a, 400 v, 50 hz 5.5 kw
terminal capacity (solid/flexible with ferrule awg) 18 - 14
ambient operating temperature (enclosed) - min -25 °c
Shock resistance 15 g, mechanical, according to iec/en 60068-2-27, half-sinusoidal shock 20 ms
number of contacts in series at dc-21a, 240 v 1
10.2.7 inscriptions meets the product standard's requirements.
10.2.2 corrosion resistance meets the product standard's requirements.
rated operational current (ie) at ac-3, 660 v, 690 v 4.9 a
Tightening torque 8.8 lb-in, screw terminals
1 nm, screw terminals
rated impulse withstand voltage (uimp) 6000 v ac
Pollution degree 3
rated operational current (ie) at ac-23a, 230 v 13.3 a
Degree of protection ip65
nema 1
nema 12
switching angle 30 °
assigned motor power at 200/208 v, 60 hz, 1-phase 1 hp
heat dissipation capacity pdiss 0 w
rated operating voltage (ue) at ac - max 690 v
number of contacts in series at dc-23a, 48 v 2
operating frequency 1200 operations/h
10.2.6 mechanical impact does not apply, since the entire switchgear needs to be evaluated.
10.6 incorporation of switching devices and components does not apply, since the entire switchgear needs to be evaluated.
rated operational power star-delta at 380/400 v, 50 hz 7.5 kw
rated breaking capacity at 500 v (cos phi to iec 60947-3) 80 a
ambient operating temperature - max 50 °c
rated making capacity up to 690 v (cos phi to iec/en 60947-3) 130 a
rated conditional short-circuit current (iq) 6 ka
rated operational current (ie) at dc-23a, 120 v 5 a
short-circuit current rating (basic rating) 5 ka, sccr (ul/csa)
50a, max. fuse, sccr (ul/csa)
inscription 1-11
10.2.3.1 verification of thermal stability of enclosures meets the product standard's requirements.
rated breaking capacity at 220/230 v (cos phi to iec 60947-3) 100 a
10.4 clearances and creepage distances meets the product standard's requirements.
10.11 short-circuit rating is the panel builder's responsibility. the specifications for the switchgear must be observed.
rated operational current for specified heat dissipation (in) 20 a
certifications ce
iec/en 60204
iec/en 60947
ul category control no.: nlrv
ul 60947-4-1
csa-c22.2 no. 94
ul file no.: e36332
vde 0660
csa file no.: 012528
csa class no.: 3211-05
csa
csa-c22.2 no. 60947-4-1-14
ul
iec/en 60947-3
product width 48 mm
product length/depth 171 mm
switching capacity (auxiliary contacts, pilot duty) a600 (ul/csa)
p300 (ul/csa)
short-circuit protection rating 20 a gg/gl, fuse, contacts
rated operational current (ie) at ac-3, 220 v, 230 v, 240 v 11.5 a
rated operational current (ie) at ac-3, 500 v 9 a
switching capacity (main contacts, general use) 16 a, rated uninterrupted current max. (ul/csa)
10.7 internal electrical circuits and connections is the panel builder's responsibility.
control circuit reliability 1 failure per 100,000 switching operations statistically determined, at 24 v dc, 10 ma)
number of switch positions 11
lifespan, mechanical 400,000 operations
rated operational power star-delta at 690 v, 50 hz 5.5 kw
rated operational current (ie) star-delta at ac-3, 690 v 8.5 a
number of contacts in series at dc-23a, 240 v 5
rated breaking capacity at 660/690 v (cos phi to iec 60947-3) 60 a
assigned motor power at 200/208 v, 60 hz, 3-phase 3 hp
uninterrupted current rated uninterrupted current iu is specified for max. cross-section.
switching capacity (auxiliary contacts, general use) 10a, iu, (ul/csa)
heat dissipation per pole, current-dependent pvid .6 w
rated operational power star-delta at 220/230 v, 50 hz 5.5 kw
10.13 mechanical function the device meets the requirements, provided the information in the instruction leaflet (il) is observed.
safety parameter (en iso 13849-1) b10d values as per en iso 13849-1, table c.1
safe isolation 440 v ac, between the contacts, according to en 61140
10.9.3 impulse withstand voltage is the panel builder's responsibility.
rated breaking capacity at 400/415 v (cos phi to iec 60947-3) 110 a
climatic proofing damp heat, constant, to iec 60068-2-78
damp heat, cyclic, to iec 60068-2-30
rated operational current (ie) at ac-23a, 690 v 7.6 a
assigned motor power at 575/600 v, 60 hz, 3-phase 7.5 hp
10.8 connections for external conductors is the panel builder's responsibility.
rated operational current (ie) at ac-21, 440 v 20 a
10.2.5 lifting does not apply, since the entire switchgear needs to be evaluated.
rated operational power at ac-23a, 220/230 v, 50 hz 3 kw
rated operational current (ie) at ac-23a, 500 v 13.3 a
rated operational current (ie) at dc-21, 240 v 1 a
number of contact units 11
assigned motor power at 230/240 v, 60 hz, 3-phase 3 hp
rated operational power at ac-3, 500 v, 50 hz 5.5 kw
rated operational current (ie) at ac-3, 380 v, 400 v, 415 v 11.5 a
10.2.4 resistance to ultra-violet (uv) radiation uv resistance only in connection with protective shield.
Type step switch
rated operational power at ac-3, 690 v, 50 hz 4 kw
voltage per contact pair in series 60 v
rated operational power at ac-23a, 500 v, 50 hz 7.5 kw
rated operational current (ie) at dc-13, control switches l/r = 50 ms 10 a
Overvoltage category iii
10.9.2 power-frequency electric strength is the panel builder's responsibility.
rated operational current (ie) at ac-23a, 400 v, 415 v 13.3 a
assigned motor power at 460/480 v, 60 hz, 3-phase 7.5 hp
number of contacts in series at dc-23a, 24 v 1
rated operational current (ie) at dc-23a, 48 v 10 a
product category control switches
10.3 degree of protection of assemblies does not apply, since the entire switchgear needs to be evaluated.
rated uninterrupted current (iu) 20 a
ambient operating temperature - min -25 °c
number of poles two-pole
assigned motor power at 115/120 v, 60 hz, 1-phase .5 hp
switch type level switch
actuator type toggle
rated operational current (ie) at dc-23a, 240 v 5 a
short-circuit current rating (high fault) 20 a, class j, max. fuse, sccr (ul/csa)
10 ka, sccr (ul/csa)
degree of protection (front side) ip65
nema 12
fitted with: black thumb grip and front plate
Design 15,296
mounting method flush mounting
rated operational current (ie) at dc-23a, 24 v 10 a
terminal capacity (flexible with ferrule) 1 x (0.75 - 2.5) mm², ferrules to din 46228
2 x (0.75 - 2.5) mm², ferrules to din 46228
catalog notes rated short-time withstand current (icw) for a time of 1 second
Product weight .339 kg
product height 48 mm
$257.82
Stock 12 pcs.
Part number 003772
Manufacturer Eaton