Eaton 003230

t3-6-15168/v/svb-sw

Limited stock only available on quotation

Specifications

Width Weight Mounting Position
65 mm 383g as required
Design 15,168
rated operational power star-delta at 690 v, 50 hz 22 kw
rated operational current (ie) star-delta at ac-3, 690 v 25.5 a
number of auxiliary contacts (normally closed contacts) 1
rated breaking capacity at 660/690 v (cos phi to iec 60947-3) 170 a
assigned motor power at 200/208 v, 60 hz, 3-phase 3 hp
uninterrupted current rated uninterrupted current iu is specified for max. cross-section.
switching capacity (auxiliary contacts, general use) 10a, iu, (ul/csa)
heat dissipation per pole, current-dependent pvid 1.1 w
rated operational power star-delta at 220/230 v, 50 hz 7.5 kw
10.13 mechanical function the device meets the requirements, provided the information in the instruction leaflet (il) is observed.
Mounting position as required
10.5 protection against electric shock does not apply, since the entire switchgear needs to be evaluated.
static heat dissipation, non-current-dependent pvs 0 w
device construction built-in device fixed built-in technique
rated operational power at ac-3, 415 v, 50 hz 11 kw
rated operational current (ie) at ac-23a, 690 v 17 a
assigned motor power at 575/600 v, 60 hz, 3-phase 10 hp
10.8 connections for external conductors is the panel builder's responsibility.
rated operational current (ie) at ac-21, 440 v 32 a
10.2.5 lifting does not apply, since the entire switchgear needs to be evaluated.
rated operational power at ac-23a, 220/230 v, 50 hz 7.5 kw
rated operational current (ie) at ac-23a, 500 v 26.4 a
rated operational current (ie) at dc-21, 240 v 1 a
ambient operating temperature (enclosed) - min -25 °c
Shock resistance 15 g, mechanical, according to iec/en 60068-2-27, half-sinusoidal shock 20 ms
number of contacts in series at dc-21a, 240 v 1
rated operational current (ie) star-delta at ac-3, 380/400 v 32 a
10.2.7 inscriptions meets the product standard's requirements.
10.2.2 corrosion resistance meets the product standard's requirements.
rated operational power at ac-3, 690 v, 50 hz 11 kw
functions stop function
interlockable
switching power at 400 v 15 kw
rated operational power at ac-23a, 500 v, 50 hz 15 kw
rated operational current (ie) at dc-13, control switches l/r = 50 ms 20 a
actuator color black
Overvoltage category iii
switching angle 90 °
assigned motor power at 200/208 v, 60 hz, 1-phase 3 hp
heat dissipation capacity pdiss 0 w
terminal capacity 2 x (1 - 6) mm², solid or stranded
1 x (0.75 - 4) mm², flexible with ferrules to din 46228
1 x (1 - 6) mm², solid or stranded
14 - 10 awg, solid or flexible with ferrule
2 x (0.75 - 4) mm², flexible with ferrules to din 46228
number of contacts in series at dc-23a, 48 v 2
operating frequency 1200 operations/h
10.2.6 mechanical impact does not apply, since the entire switchgear needs to be evaluated.
10.6 incorporation of switching devices and components does not apply, since the entire switchgear needs to be evaluated.
rated operational power star-delta at 380/400 v, 50 hz 15 kw
rated breaking capacity at 500 v (cos phi to iec 60947-3) 240 a
Features version as maintenance-/service switch
version as main switch
ambient operating temperature - max 50 °c
actuator type door coupling rotary drive
rated operational current (ie) at dc-23a, 240 v 5 a
short-circuit current rating (high fault) 10 ka, sccr (ul/csa)
40 a, class j, max. fuse, sccr (ul/csa)
degree of protection (front side) ip65
number of switches 1
lifespan, mechanical 500,000 operations
mounting method rear mounting
rated operational power at ac-3, 380/400 v, 50 hz 11 kw
10.11 short-circuit rating is the panel builder's responsibility. the specifications for the switchgear must be observed.
catalog notes rated short-time withstand current (icw) for a time of 1 second
Product weight .383 kg
product height 74 mm
ean 4015080032304
number of contacts in series at dc-23a, 60 v 3
rated operational current (ie) star-delta at ac-3, 500 v 32 a
rated operational current (ie) star-delta at ac-3, 220/230 v 32 a
assigned motor power at 230/240 v, 60 hz, 1-phase 3 hp
number of contacts in series at dc-23a, 120 v 3
10.10 temperature rise the panel builder is responsible for the temperature rise calculation. eaton will provide heat dissipation data for the devices.
rated operational voltage (ue) at ac - max 690 v
10.2.3.3 resist. of insul. mat. to abnormal heat/fire by internal elect. effects meets the product standard's requirements.
10.2.3.2 verification of resistance of insulating materials to normal heat meets the product standard's requirements.
rated operational current (ie) at dc-1, load-break switches l/r = 1 ms 25 a
number of contacts in series at dc-23a, 240 v 5
suitable for ground mounting
branch circuits, suitable as motor disconnect, (ul/csa)
intermediate mounting
equipment heat dissipation, current-dependent pvid 0 w
rated operating voltage (ue) - min 690 v
rated operational power star-delta at 500 v, 50 hz 18.5 kw
10.9.4 testing of enclosures made of insulating material is the panel builder's responsibility.
rated operational power at ac-23a, 690 v, 50 hz 15 kw
safety parameter (en iso 13849-1) b10d values as per en iso 13849-1, table c.1
safe isolation 440 v ac, between the contacts, according to en 61140
10.9.3 impulse withstand voltage is the panel builder's responsibility.
rated breaking capacity at 400/415 v (cos phi to iec 60947-3) 260 a
climatic proofing damp heat, cyclic, to iec 60068-2-30
damp heat, constant, to iec 60068-2-78
rated permanent current at ac-21, 400 v 32 a
load rating 1.6 x iₑ (with intermittent operation class 12, 40 % duty factor)
2 x iₑ (with intermittent operation class 12, 25 % duty factor)
1.3 x iₑ (with intermittent operation class 12, 60 % duty factor)
screw size m4, terminal screw
rated operational voltage (ue) at ac - min 690 v
ambient operating temperature (enclosed) - max 40 °c
10.12 electromagnetic compatibility is the panel builder's responsibility. the specifications for the switchgear must be observed.
rated operational current (ie) at dc-23a, 60 v 25 a
rated operational power at ac-23a, 400 v, 50 hz 15 kw
number of contact units 6
assigned motor power at 230/240 v, 60 hz, 3-phase 3 hp
rated operational power at ac-3, 500 v, 50 hz 15 kw
number of auxiliary contacts (normally open contacts) 2
rated operational current (ie) at ac-3, 380 v, 400 v, 415 v 23.7 a
10.2.4 resistance to ultra-violet (uv) radiation uv resistance only in connection with protective shield.
rated operational current (ie) at ac-3, 660 v, 690 v 14.7 a
Tightening torque 1.6 nm, screw terminals
17.7 lb-in, screw terminals
voltage per contact pair in series 60 v
rated impulse withstand voltage (uimp) 6000 v ac
Pollution degree 3
rated operational current (ie) at ac-23a, 230 v 32 a
Degree of protection nema 12
10.9.2 power-frequency electric strength is the panel builder's responsibility.
rated operational current (ie) at ac-23a, 400 v, 415 v 32 a
assigned motor power at 460/480 v, 60 hz, 3-phase 7.5 hp
number of contacts in series at dc-23a, 24 v 1
rated operational current (ie) at dc-23a, 48 v 25 a
product category main switch
10.3 degree of protection of assemblies does not apply, since the entire switchgear needs to be evaluated.
rated uninterrupted current (iu) 32 a
ambient operating temperature - min -25 °c
number of poles 9
electrical connection type of main circuit screw connection
assigned motor power at 115/120 v, 60 hz, 1-phase 1.5 hp
rated making capacity up to 690 v (cos phi to iec/en 60947-3) 320 a
rated conditional short-circuit current (iq) 1 ka
rated operational current (ie) at dc-23a, 120 v 12 a
short-circuit current rating (basic rating) 5 ka, sccr (ul/csa)
40a, max. fuse, sccr (ul/csa)
fitted with: black rotary handle and locking ring
10.2.3.1 verification of thermal stability of enclosures meets the product standard's requirements.
rated breaking capacity at 220/230 v (cos phi to iec 60947-3) 260 a
10.4 clearances and creepage distances meets the product standard's requirements.
rated operational current (ie) at dc-23a, 24 v 25 a
rated operational current for specified heat dissipation (in) 32 a
certifications iec/en 60947
iec/en 60947-3
csa file no.: 012528
csa-c22.2 no. 94
iec/en 60204
ul category control no.: nlrv
ul
vde 0660
ul file no.: e36332
csa-c22.2 no. 60947-4-1-14
csa
csa class no.: 3211-05
ul 60947-4-1
ce
product width 65 mm
product length/depth 179 mm
control circuit reliability 1 failure per 100,000 switching operations statistically determined, at 24 v dc, 10 ma)
switching capacity (auxiliary contacts, pilot duty) a600 (ul/csa)
p600 (ul/csa)
short-circuit protection rating 35 a gg/gl, fuse, contacts
rated operational current (ie) at ac-3, 220 v, 230 v, 240 v 23.7 a
rated operational current (ie) at ac-3, 500 v 23.7 a
switching capacity (main contacts, general use) 25 a, rated uninterrupted current max. (ul/csa)
10.7 internal electrical circuits and connections is the panel builder's responsibility.
rated short-time withstand current (icw) 650 a, contacts, 1 second
0.65 ka