Standard nominal flow rate | 870 l/min | ||
Type of actuation | Manual | ||
Material lever | PA-reinforced | ||
Material seals | NBR | ||
Note on materials | RoHS-compliant | ||
Pneumatic connection, port 2 | G1/4 | ||
Type of mounting | Front panel mounting With through-hole Either: | ||
Max. lateral force on actuation | 200 N | ||
Actuating torque | 0,4 Nm | ||
Media temperature | -10 °C ... 60 °C | ||
Corrosion resistance class CRC | 1 - Low corrosion stress | ||
Operating medium | Compressed air to ISO 8573-1:2010 [7:-:-] | ||
Max. switching frequency | 0,5 Hz | ||
Symbol | 995,893 | ||
Type of piloting | Direct | ||
Sealing principle | Soft | ||
Exhaust-air function | With flow control option | ||
Type of reset | Mechanical spring | ||
Operating pressure | -0,95 bar ... 10 bar |
Construction width | 20 mm | ||
Valve function | 3/2-way, monostable, open/closed | ||
Material housing | Anodised wrought aluminium alloy | ||
Material cover | PA-reinforced | ||
Pneumatic connection, port 3 | G1/4 | ||
Pneumatic connection, port 1 | G1/4 | ||
Product weight | 200 g | ||
Max. force on actuation | 200 N | ||
Ambient temperature | -10 °C ... 60 °C | ||
LABS (PWIS) conformity | VDMA24364-B1/B2-L | ||
Note on operating and pilot medium | Lubricated operation possible (in which case lubricated operation will always be required) | ||
Explosion protection | Zone 1 (ATEX) Zone 2 (ATEX) Zone 21 (ATEX) Zone 22 (ATEX) | ||
lap | Zero overlap | ||
Flow direction | Reversible | ||
Mounting position | optional | ||
Instructions on use | Actuate manually only | ||
Nominal size | 6 mm | ||
Design | Poppet seat | ||
pneumatic working port | G1/4 |