terminal capacity (aluminum solid conductor/cable) | 10 mm² - 16 mm² (1x) direct at switch rear-side connection 10 mm² - 16 mm² (2x) direct at switch rear-side connection 16 mm² (1x) at tunnel terminal |
||
Shock resistance | 20 g (half-sinusoidal shock 20 ms) | ||
circuit breaker frame type | pn1 | ||
isolation | 300 v ac (between the auxiliary contacts) 500 v ac (between auxiliary contacts and main contacts) |
||
10.2.7 inscriptions | meets the product standard's requirements. | ||
10.2.2 corrosion resistance | meets the product standard's requirements. | ||
rated operating power at ac-3, 400 v | 0 kw | ||
rated conditional short-circuit current with downstream fuse | 10 ka at 690 v 160 gr 100 ka at 400/415 v |
||
functions | interlockable disconnectors/main switches |
||
10.7 internal electrical circuits and connections | is the panel builder's responsibility. | ||
optional terminals | connection on rear. screw terminal. tunnel terminal | ||
rated short-time withstand current (t = 0.3 s) | 2 ka | ||
rated impulse withstand voltage (uimp) at auxiliary contacts | 6000 v | ||
Overvoltage category | iii | ||
10.9.2 power-frequency electric strength | is the panel builder's responsibility. | ||
degree of protection (terminations) | ip10 (tunnel terminal) ip00 (terminations, phase isolator and band terminal) |
||
voltage rating | 690 v - 690 v | ||
rated operating power at ac-23, 400 v | 90 kw | ||
10.2.3.3 resist. of insul. mat. to abnormal heat/fire by internal elect. effects | meets the product standard's requirements. | ||
rated conditional short-circuit current (iq) | 0 ka | ||
rated short-circuit making capacity icm at 690 v, 50/60 hz | 2.8 ka | ||
rated operating voltage (ue) at ac - max | 690 v | ||
Application | use in unearthed supply systems at 690 v | ||
10.9.4 testing of enclosures made of insulating material | is the panel builder's responsibility. | ||
10.13 mechanical function | the device meets the requirements, provided the information in the instruction leaflet (il) is observed. | ||
used with | enclosure 100 x 800 x 800 mm | ||
10.6 incorporation of switching devices and components | does not apply, since the entire switchgear needs to be evaluated. | ||
ambient operating temperature - min | -25 °c | ||
number of poles | three-pole | ||
rated impulse withstand voltage (uimp) at main contacts | 6000 v | ||
lifespan, electrical | 5000 operations at 690 v ac-1 7500 operations at 415 v ac-1 1000 operations at 400 v ac-23a 1000 operations at 415 v ac-23a 1000 operations at 690 v ac-23a 7500 operations at 400 v ac-1 |
||
terminal capacity (copper stranded conductor/cable) | 25 mm² - 70 mm² (1x) direct at switch rear-side connection 6 mm² - 25 mm² (2x) at box terminal 25 mm² - 95 mm² (1x) at 1-hole tunnel terminal 10 mm² - 70 mm² (1x) at box terminal 25 mm² (2x) direct at switch rear-side connection terminal capacity hint: up to 95 mm² can be connected depending on the cable manufacturer |
||
rated permanent current at ac-21, 400 v | 0 a | ||
special features | main switch characteristics including positive drive to iec/en 60204 and vde 0113. isolating characteristics to iec/en 60947-3 and vde 0660. busbar tag shroud to vde 0160 part 100. rated current = rated uninterrupted current: 160 a |
||
10.8 connections for external conductors | is the panel builder's responsibility. | ||
protection against direct contact | finger and back-of-hand proof to din en 50274/vde 0106 part 110 | ||
ambient storage temperature - min | 40 °c | ||
handle type | rocker lever | ||
10.2.5 lifting | does not apply, since the entire switchgear needs to be evaluated. | ||
mounting method | fixed built-in device fixed built-in technique distribution board installation ground mounting intermediate mounting |
||
10.4 clearances and creepage distances | meets the product standard's requirements. | ||
rated operational current for specified heat dissipation (in) | 160 a | ||
compliances | rohs conform | ||
product width | 90 mm | ||
product length/depth | 88 mm |
rated insulation voltage (ui) | 690 v | ||
direction of incoming supply | as required | ||
number of operations per hour - max | 120 | ||
rated permanent current at ac-23, 400 v | 0 a | ||
10.2.4 resistance to ultra-violet (uv) radiation | meets the product standard's requirements. | ||
Type | switch-disconnector | ||
standard terminals | box terminal | ||
switching power at 400 v | 0 kw | ||
10.10 temperature rise | the panel builder is responsible for the temperature rise calculation. eaton will provide heat dissipation data for the devices. | ||
Pollution degree | 3 | ||
ambient storage temperature - max | 70 °c | ||
rated short-time withstand current (icw) | 2 ka | ||
rated short-time withstand current (t = 1 s) | 2 ka | ||
Degree of protection | ip20 (basic protection type, in the area of the hmi devices) | ||
terminal capacity (aluminum stranded conductor/cable) | 25 mm² - 95 mm² (1x) at 1-hole tunnel terminal | ||
terminal capacity (copper solid conductor/cable) | 10 mm² - 16 mm² (1x) direct at switch rear-side connection 10 mm² - 16 mm² (1x) at box terminal 6 mm² - 16 mm² (2x) at box terminal 6 mm² - 16 mm² (2x) direct at switch rear-side connection 16 mm² (1x) at tunnel terminal |
||
rated operating frequency | 50 hz | ||
lifespan, mechanical | 20000 operations | ||
10.2.3.2 verification of resistance of insulating materials to normal heat | meets the product standard's requirements. | ||
rated conditional short-circuit current with back-up fuse | 100 ka at 400/415 v 160 gr 80 ka at 690 v |
||
degree of protection (ip), front side | ip20 ip66 (with door coupling rotary handle) ip40 (with insulating surround) |
||
10.3 degree of protection of assemblies | does not apply, since the entire switchgear needs to be evaluated. | ||
rated operational current | 160 a (415 v ac-22/23a, making and breaking capacity) 160 a (690 v ac-22/23a, making and breaking capacity) |
||
10.2.6 mechanical impact | does not apply, since the entire switchgear needs to be evaluated. | ||
equipment heat dissipation, current-dependent | 29.18 w | ||
10.5 protection against electric shock | does not apply, since the entire switchgear needs to be evaluated. | ||
handle color | black | ||
switch positions | i, 0 | ||
10.9.3 impulse withstand voltage | is the panel builder's responsibility. | ||
electrical connection type of main circuit | frame clamp | ||
Features | version as emergency stop installation version as maintenance-/service switch version as main switch |
||
climatic proofing | damp heat, cyclic, to iec 60068-2-30 damp heat, constant, to iec 60068-2-78 |
||
ambient operating temperature - max | 70 °c | ||
short-circuit protective device fuses - max | 160 a gl | ||
terminal capacity (copper busbar) | m6 at rear-side screw connection max. 16 mm x 5 mm direct at switch rear-side connection min. 12 mm x 5 mm direct at switch rear-side connection |
||
number of switches | 1 | ||
10.2.3.1 verification of thermal stability of enclosures | meets the product standard's requirements. | ||
terminal capacity (copper strip) | max. 9 segments of 9 mm x 0.8 mm at box terminal min. 2 segments of 9 mm x 0.8 mm at box terminal |
||
amperage rating | 160 a | ||
10.12 electromagnetic compatibility | is the panel builder's responsibility. the specifications for the switchgear must be observed. | ||
10.11 short-circuit rating | is the panel builder's responsibility. the specifications for the switchgear must be observed. | ||
certifications | iec/en 60947 iec |
||
Product weight | .886 kg | ||
product height | 145 mm | ||
ean | 4015082812355 |