terminal capacity (aluminum solid conductor/cable) | 10 mm² - 16 mm² (2x) direct at switch rear-side connection 16 mm² (1x) at tunnel terminal 10 mm² - 16 mm² (1x) direct at switch rear-side connection |
||
direction of incoming supply | as required | ||
number of operations per hour - max | 120 | ||
ean | 4015082590772 | ||
rated short-circuit making capacity icm at 440 v, 50/60 hz | 53 ka | ||
10.2.4 resistance to ultra-violet (uv) radiation | meets the product standard's requirements. | ||
Type | circuit breaker | ||
rated short-circuit making capacity icm at 400/415 v, 50/60 hz | 53 ka | ||
functions | system and cable protection | ||
10.7 internal electrical circuits and connections | is the panel builder's responsibility. | ||
optional terminals | connection on rear. screw terminal. tunnel terminal | ||
ambient storage temperature - max | 70 °c | ||
short delay current setting (isd) - max | 0 a | ||
Degree of protection | ip20 (basic degree of protection, in the operating controls area) ip20 |
||
10.9.2 power-frequency electric strength | is the panel builder's responsibility. | ||
degree of protection (terminations) | ip10 (tunnel terminal) ip00 (terminations, phase isolator and strip terminal) |
||
voltage rating | 440 v - 440 v | ||
lifespan, mechanical | 20000 operations | ||
10.2.3.2 verification of resistance of insulating materials to normal heat | meets the product standard's requirements. | ||
overload current setting (ir) - min | 50 a | ||
degree of protection (ip), front side | ip40 (with insulating surround) ip66 (with door coupling rotary handle) |
||
rated short-circuit making capacity icm at 240 v, 50/60 hz | 63 ka | ||
Application | use in unearthed supply systems at 440 v | ||
10.9.4 testing of enclosures made of insulating material | is the panel builder's responsibility. | ||
10.13 mechanical function | the device meets the requirements, provided the information in the instruction leaflet (il) is observed. | ||
equipment heat dissipation, current-dependent | 14.17 w | ||
10.5 protection against electric shock | does not apply, since the entire switchgear needs to be evaluated. | ||
ambient operating temperature - min | -25 °c | ||
utilization category | a (iec/en 60947-2) | ||
rated short-circuit breaking capacity ics (iec/en 60947) at 400/415 v, 50/60 hz | 25 ka | ||
short-circuit total breaktime | < 10 ms | ||
lifespan, electrical | 7500 operations at 415 v ac-1 7500 operations at 400 v ac-1 |
||
terminal capacity (copper stranded conductor/cable) | 10 mm² - 70 mm² (1x) at box terminal 25 mm² - 95 mm² (1x) at 1-hole tunnel terminal 25 mm² (2x) direct at switch rear-side connection 6 mm² - 25 mm² (2x) at box terminal 10 mm² - 70 mm² (1x) direct at switch rear-side connection |
||
position of connection for main current circuit | front side | ||
special features | maximum back-up fuse, if the expected short-circuit currents at the installation location exceed the switching capacity of the circuit breaker (rated short-circuit breaking capacity icn) rated current = rated uninterrupted current: 63 a terminal capacity hint: up to 95 mm² can be connected depending on the cable manufacturer. |
||
terminal capacity (copper busbar) | m6 at rear-side screw connection min. 12 mm x 5 mm direct at switch rear-side connection max. 16 mm x 5 mm direct at switch rear-side connection |
||
ambient storage temperature - min | 40 °c | ||
handle type | rocker lever | ||
10.2.5 lifting | does not apply, since the entire switchgear needs to be evaluated. | ||
mounting method | din rail (top hat rail) mounting optional fixed built-in device fixed built-in technique |
||
10.4 clearances and creepage distances | meets the product standard's requirements. | ||
rated operational current for specified heat dissipation (in) | 63 a | ||
compliances | rohs conform | ||
product width | 90 mm |
Shock resistance | 20 g (half-sinusoidal shock 20 ms) | ||
circuit breaker frame type | nzm1 | ||
product length/depth | 88 mm | ||
isolation | 500 v ac (between auxiliary contacts and main contacts) 300 v ac (between the auxiliary contacts) |
||
10.2.7 inscriptions | meets the product standard's requirements. | ||
10.2.2 corrosion resistance | meets the product standard's requirements. | ||
standard terminals | box terminal | ||
short-circuit release non-delayed setting - max | 630 a | ||
10.10 temperature rise | the panel builder is responsible for the temperature rise calculation. eaton will provide heat dissipation data for the devices. | ||
Pollution degree | 3 | ||
release system | thermomagnetic release | ||
rated impulse withstand voltage (uimp) at auxiliary contacts | 6000 v | ||
Overvoltage category | iii | ||
short-circuit release non-delayed setting - min | 378 a | ||
terminal capacity (aluminum stranded conductor/cable) | 25 mm² - 95 mm² (1x) at tunnel terminal 25 mm² - 35 mm² (2x) direct at switch rear-side connection 25 mm² - 35 mm² (1x) direct at switch rear-side connection |
||
terminal capacity (copper solid conductor/cable) | 16 mm² (1x) at tunnel terminal 10 mm² - 16 mm² (1x) at box terminal 10 mm² - 16 mm² (1x) direct at switch rear-side connection 6 mm² - 16 mm² (2x) at box terminal 6 mm² - 16 mm² (2x) direct at switch rear-side connection |
||
overload current setting (ir) - max | 63 a | ||
10.2.3.3 resist. of insul. mat. to abnormal heat/fire by internal elect. effects | meets the product standard's requirements. | ||
short delay current setting (isd) - min | 0 a | ||
instantaneous current setting (ii) - max | 630 a | ||
rated short-circuit breaking capacity ics (iec/en 60947) at 440 v, 50/60 hz | 18.5 ka | ||
10.3 degree of protection of assemblies | does not apply, since the entire switchgear needs to be evaluated. | ||
rated short-circuit breaking capacity ics (iec/en 60947) at 230 v, 50/60 hz | 30 ka | ||
10.2.6 mechanical impact | does not apply, since the entire switchgear needs to be evaluated. | ||
instantaneous current setting (ii) - min | 380 a | ||
terminal capacity (control cable) | 0.75 mm² - 2.5 mm² (1x) 0.75 mm² - 1.5 mm² (2x) |
||
10.6 incorporation of switching devices and components | does not apply, since the entire switchgear needs to be evaluated. | ||
number of poles | three-pole | ||
10.9.3 impulse withstand voltage | is the panel builder's responsibility. | ||
rated impulse withstand voltage (uimp) at main contacts | 6000 v | ||
electrical connection type of main circuit | frame clamp | ||
Features | protection unit | ||
climatic proofing | damp heat, cyclic, to iec 60068-2-30 damp heat, constant, to iec 60068-2-78 |
||
ambient operating temperature - max | 70 °c | ||
10.8 connections for external conductors | is the panel builder's responsibility. | ||
protection against direct contact | finger and back-of-hand proof to din en 50274/vde 0106 part 110 | ||
10.2.3.1 verification of thermal stability of enclosures | meets the product standard's requirements. | ||
terminal capacity (copper strip) | min. 2 segments of 9 mm x 0.8 mm at box terminal max. 9 segments of 9 mm x 0.8 mm at box terminal |
||
amperage rating | 63 a | ||
10.12 electromagnetic compatibility | is the panel builder's responsibility. the specifications for the switchgear must be observed. | ||
10.11 short-circuit rating | is the panel builder's responsibility. the specifications for the switchgear must be observed. | ||
certifications | iec/en 60947 iec |
||
Product weight | 1.051 kg | ||
product height | 145 mm |