| Material del cuerpo | PBT-reinforced | ||
| Electrical connection PLC | M12 Plugs 8-pin | ||
| Switching logic for outputs | PNP (positive switching) | ||
| Characteristic for inputs | To EN 61131-2 | ||
| Error de linealidad FS | 0,2 % | ||
| Temperatura ambiente | 0 °C ... 55 °C | ||
| Humedad relativa del aire | 95 % Non-condensing | ||
| Conformidad PWIS | VDMA24364-B1/B2-L | ||
| CE marking (see declaration of conformity) | To UK instructions for EMC To UK RoHS instructions | ||
| Símbolo KC | KC-EMV | ||
| Fluctuaciones de tensión admisibles | +/- 25% | ||
| Ondulación residual | 4 Vpp | ||
| Tensión nominal de funcionamiento DC | 24 V | ||
| Power supply requirements | PELV | ||
| Precisión de repetición | Min. ± 0.1 mm | ||
| Resistencia a cortocircuitos | yes | ||
| Función de diagnóstico | Display via LED |
| Tipo de fijación | With through-hole | ||
| Electrical connection measuring system | M12 Socket 8-pin | ||
| Switching logic for inputs | PNP (positive switching) | ||
| Characteristic for outputs | To EN 61131-2 | ||
| Peso del producto | 128 g | ||
| Grado de protección | IP65 IP67 | ||
| Temperatura de almacenamiento | -20 °C ... 70 °C | ||
| Clase de resistencia a la corrosión CRC | 1 - Low corrosion stress | ||
| Marcado CE (véase la declaración de conformidad) | To EU EMC Directive In accordance with EU RoHS Directive | ||
| Certificación | RCM trademark | ||
| Current consumption at nominal operating voltage | 20 mA ... 30 mA | ||
| Power failure buffering for logic voltage | 10 ms | ||
| Debounce time for inputs | 3 ms | ||
| Salida analógica | 4 - 20 mA To EN 61131-2 | ||
| Protección contra inversión de polaridad | For PLC plug S1 | ||
| Posición de montaje | optional |