Operating voltage | 24V DC | ||
Standard nominal flow rate | 1.000 l/min | ||
Type of actuation | Electric | ||
Material housing | Die-cast aluminium | ||
Note on materials | RoHS-compliant | ||
Electrical connection | 3-pin M12x1 Central plug Round design | ||
Max. tightening torque for valve mounting | 1,8 Nm ... 2,2 Nm | ||
Pilot medium | Compressed air to ISO 8573-1:2010 [7:4:4] | ||
Media temperature | -5 °C ... 50 °C | ||
Shock resistance | Shock test with severity level 2 to FN 942017-5 and EN 60068-2-27 | ||
Note on operating and pilot medium | Lubricated operation possible (in which case lubricated operation will always be required) | ||
Permissible voltage fluctuations | +/- 10 % | ||
Nominal current with current reduction | 30 mA after 20 ms | ||
Max. negative test pulse with 1 signal | 500 µs | ||
Duty cycle | 100% | ||
Switching time off | 52 ms | ||
Flow rate of valve on individual sub-base | 1.100 l/min | ||
C value | 4,35 l/sbar | ||
Signal status display | LED | ||
Symbol | 991,080 | ||
Pilot air supply | Internal | ||
Manual override | Non-detenting | ||
Mounting position | optional | ||
Exhaust-air function | With flow control option Via throttle plate Via individual sub-base | ||
Nominal size | 9 mm | ||
CE marking (see declaration of conformity) | To UK instructions for EMC To UK RoHS instructions | ||
Approval | RCM trademark c UL us - Recognized (OL) | ||
Design | Piston gate valve |
pneumatic working port | Sub-base size 26 mm to ISO 15407-1 | ||
Construction width | 26 mm | ||
Valve function | 5/3 closed | ||
Material seals | FPM HNBR NBR | ||
Type of mounting | On sub-base Via through-hole and screw | ||
Product weight | 270 g | ||
Ambient temperature | -5 °C ... 50 °C | ||
Relative air humidity | 0 - 90% | ||
Corrosion resistance class CRC | 2 - Moderate corrosion stress | ||
Vibration resistance | Transport application test with severity level 2 to FN 942017-4 and EN 60068-2-6 | ||
Operating medium | Compressed air to ISO 8573-1:2010 [7:4:4] | ||
Characteristic coil data | 24 V DC: low-current phase 1.0 W, high-current phase 2.4 W | ||
Nominal pick-up current per solenoid coil | 110 mA up to 20 ms | ||
Max. positive test pulse with 0 signal | 500 µs | ||
Switching time on | 20 ms | ||
Flow rate of pneumatically interlinked valve | 1.000 l/min | ||
Flow rate of valve | 1.400 l/min | ||
b value | 0,24 | ||
lap | Positive overlap | ||
Flow direction | Non-reversible | ||
Type of piloting | Pilot actuated | ||
Conforms to standard | ISO 15407-1 | ||
Sealing principle | Soft | ||
Grid dimension | 27 mm | ||
Degree of protection | IP65 NEMA 4 | ||
CE mark (see declaration of conformity) | To EU EMC Directive | ||
Type of reset | Mechanical spring | ||
Operating pressure | 3 bar ... 8 bar |