| Material del cuerpo | PA | ||
| Tipo de fijación | With H-rail | ||
| Service interface, number of pins/wires | 5 | ||
| Service interface, connection type | Socket | ||
| Fieldbus interface, max. address volume for outputs | 64 Byte | ||
| Fieldbus interface, connection pattern | 00995638 | ||
| Interfaz de bus de campo, cantidad de contactos/hilos | 9 | ||
| Interfaz de bus de campo, tipo de conexión | Socket | ||
| Interfaz de bus de campo | PROFIBUS | ||
| Field bus interface, electrical isolation | yes | ||
| Max. address volume, inputs | 64 Byte | ||
| Max. address volume, outputs | 64 Byte | ||
| Note on ambient temperature | -5 - 60°C for vertical installation | ||
| Grado de protección | IP20 | ||
| Humedad relativa del aire | 95 % Non-condensing | ||
| Clase de resistencia a la corrosión CRC | 0 - No corrosion stress | ||
| Resistencia a las vibraciones | Transport application test with severity level 1 to FN 942017-4 and EN 60068-2-6 | ||
| Marcado CE (véase la declaración de conformidad) | To EU EMC Directive | ||
| Certificación | RCM trademark c UL us listed (OL) | ||
| Power supply, conductor diameter | 0,2 mm² ... 1,5 mm² | ||
| Power supply, number of pins/wires | 4 | ||
| Power supply, connection type | Terminal strip | ||
| Permissible voltage fluctuations for electronics/sensors | ± 25% | ||
| Nominal DC operating voltage, electronics/sensors | 24 V | ||
| Intrinsic current consumption at nominal operating voltage for electronics/sensors | Typically 75 mA | ||
| Module parameters | Undervoltage diagnostics Process value representation of analogue modules | ||
| Max. number of modules | 10 | ||
| Diagnostics via LED | Bus fault Force mode Power supply, electronics/sensors Load power supply System fault | ||
| Dimensiones: ancho x largo x alto | 42.2 x 125.8 x 76.5 mm |
| Nota sobre el material | Contains paint-wetting impairment substances RoHS-compliant | ||
| Service interface, connection pattern | 00995868 | ||
| Service interface, connection technology | USB 2.0 type B mini | ||
| Service interface, function | Diagnostics and parameterisation | ||
| Fieldbus interface, max. address volume for inputs | 64 Byte | ||
| Interfaz de bus de campo, protocolo | PROFIBUS DP | ||
| Interfaz de bus de campo, técnica de conexión | Sub-D | ||
| Fieldbus interface, function | Bus connection incoming/outgoing | ||
| Field bus interface, transmission rate | 1.5 Mbps 12 Mbit/s 187.5 kbit/s 19.2 kbit/s 3 Mbit/s 500 kbit/s 6 Mbit/s 9.6 kbit/s 93.75 kbit/s | ||
| Note on inputs | 62 bytes with I/O diagnostic interface 63 bytes with status bits 64 bytes without diagnostics | ||
| Note on outputs | 62 bytes with I/O diagnostic interface 64 bytes with status bits 64 bytes without diagnostics | ||
| Peso del producto | 145 g | ||
| Temperatura ambiente | -5 °C ... 50 °C | ||
| Protection against direct and indirect contact | PELV | ||
| Temperatura de almacenamiento | -20 °C ... 70 °C | ||
| Resistencia a los golpes | Shock test with severity level 1 to FN 942017-5 and EN 60068-2-27 | ||
| Organismo que expide el certificado | UL E239998 | ||
| Símbolo KC | KC-EMV | ||
| Power supply, note on conductor diameter | 0.2 - 2.5 mm² for flexible conductors without wire end sleeves | ||
| Power supply, connection pattern | 00995847 | ||
| power supply, connection system | Spring-loaded terminal | ||
| Power supply, function | Electronics and sensors | ||
| Power failure bridging | 20 ms | ||
| Max. power supply | 8 A | ||
| Operator controls | DIL switch | ||
| System parameters | Diagnostic memory Fail-safe response Force mode System start | ||
| Configuration support | GSD file | ||
| Patrón uniforme | 18,9 mm | ||
| Diagnostics via bus | Wire break Short circuit Parameterisation error Overflow buffer Upper limit value violated Transmission error Lower limit value not observed Undervoltage Watchdog/I/O status Requested function not supported Not ready for data exchange |
| Stock | Pedir cotización |
|---|---|
| Referencia | 4080496 |
| Fabricante | FESTO |
| Unidades | Precio / Unidad |
|---|---|
| 1+ | $654,18 |