Symbol | 995,410 | ||
Corrosion resistance class CRC | 2 - Moderate corrosion stress | ||
Setting range hysteresis | 0 % ... 90 % | ||
Protection against tampering | IO-Link PIN code | ||
Displayable units | MPa bar inH2O inHg kPa kgf/cm² mmHg psi | ||
Product weight | 70 g | ||
Mounting position | optional | ||
Electrical connection 1, connection pattern | 995,386 | ||
Electrical connection 1, connector system | M12x1, A-coded to EN 61076-2-101 | ||
Reverse polarity protection | For all electrical connections | ||
IO-Link, Data storage required | 500 Byte | ||
IO-Link, Process data content IN | 14 bit PDV (pressure measurement value) 2 bit BDC (pressure monitoring) | ||
IO-Link, Process data length OUT | 0 bytes | ||
IO-Link, SIO-Mode support | Yes | ||
IO-Link, Function classes | Binary data channel (BDC) Process data variable (PDV) Identification Diagnostics Teach channel | ||
IO-Link, Protocol version | Device V 1.1 | ||
Short circuit current rating | yes | ||
Max. load resistance current output | 500 Ohm | ||
Analogue output | 0 - 10 V 4 - 20 mA 1 - 5 V | ||
Switching element function | N/C or N/O contact, switchable | ||
Switching output | 2 x PNP or 2 x NPN, switchable | ||
Repetition accuracy in ± %FS | 0,3 %FS | ||
Resolution ADC | 12 bit | ||
Media temperature | 0 °C ... 50 °C | ||
Operating medium | Compressed air to ISO 8573-1:2010 [7:4:4] Inert gases | ||
End value for pressure measuring range | -1 bar | ||
Measurement method | Piezoresistive pressure sensor | ||
Note on materials | RoHS-compliant | ||
CE marking (see declaration of conformity) | To UK instructions for EMC To UK RoHS instructions | ||
Approval | RCM trademark c UL us listed (OL) |
LABS (PWIS) conformity | VDMA24364-B1/B2-L | ||
Degree of protection | IP65 IP67 | ||
Setting range threshold value | 0 % ... 100 % | ||
Setting options | IO-Link® Teach-in Via display and keys | ||
Display type | Illuminated LCD | ||
Pneumatic connection | QS-5/32 | ||
Type of mounting | Front panel mounting | ||
Electrical connection 1, number of connections/cores | 4 | ||
Electrical connection 1, connection type | Plugs | ||
Operational voltage range DC | 20 V ... 30 V | ||
IO-Link, Min. cycle time | 3 ms | ||
IO-Link, Process data length IN | 2 bytes | ||
IO-Link, Port class | A | ||
IO-Link, communication mode | COM2 (38.4 kBaud) | ||
IO-Link, Profile | Smart sensor profile | ||
Protocol | IO-Link® | ||
Min. load resistance voltage output | 10 kOhm | ||
Rise time | 3 ms | ||
Max. output current | 100 mA | ||
Switching function | Freely programmable | ||
Temperature coefficient in ± %FS/K | 0,05 %FS/K | ||
Accuracy in ± % FS | 1,5 %FS | ||
Ambient temperature | 0 °C ... 50 °C | ||
Note on operating and pilot medium | Lubricated operation possible | ||
Max. overload pressure | 5 bar | ||
Start value for pressure measuring range | 0 bar | ||
Measured variable | Relative pressure | ||
KC mark | KC-EMV | ||
CE mark (see declaration of conformity) | To EU EMC Directive In accordance with EU RoHS Directive |