1)
Set screw M3
2)
Activation point
Activation point (dimension "X") | 9 | mm |
Functional principle | Magnetic | ||
Load current | 500 | mA | |
Connection type | Line 0.3 m and plug M8x1 3-pin with knurled screws | ||
Short-circuit protection | ‒ | ||
Switch-on suppression | ‒ | ||
Pulse delay (Off delay) | ‒ | ||
Suitable for flexing installation (Technical data only for the cast-on connection line (0.3 m) at the magnetic sensor. Even more performance, e.g. extension cables are offered for use in a cable management chain. ) | ‒ | ||
Weld spark resistant (Technical data only for the cast-on connection line (0.3 m) at the magnetic sensor. Even more performance, e.g. extension cables are offered for use in a cable management chain. ) | ‒ | ||
Cable diameter D (Technical data only for the cast-on connection line (0.3 m) at the magnetic sensor. Even more performance, e.g. extension cables are offered for use in a cable management chain. ) | 3.2 mm ±0.2 | ||
Bending radius, flexing (Technical data only for the cast-on connection line (0.3 m) at the magnetic sensor. Even more performance, e.g. extension cables are offered for use in a cable management chain. ) | ‒ | ||
Maximum permissible travel speed (Technical data only for the cast-on connection line (0.3 m) at the magnetic sensor. Even more performance, e.g. extension cables are offered for use in a cable management chain. ) | ‒ | ||
Permissible ambient temperature (min ... max) | -40 °C ... +85 °C | ||
MTTFd (as per EN ISO 13849-1 ) | ‒ |
Operating voltage | 30 | V DC | |
Switching function | REED / single-pole changeover, (NC: C+NC, NO: C+NO) | ||
Function indication | ‒ | ||
Reverse polarity protection | ‒ | ||
Switching frequency | 2.50 | kHz | |
Maximum permissible starting speed | 2 | m/s | |
Can withstand torsion (Technical data only for the cast-on connection line (0.3 m) at the magnetic sensor. Even more performance, e.g. extension cables are offered for use in a cable management chain. ) | ‒ | ||
Cable cross-section (Technical data only for the cast-on connection line (0.3 m) at the magnetic sensor. Even more performance, e.g. extension cables are offered for use in a cable management chain. ) | 3x0,14 | ||
Bending radius, stationary (Technical data only for the cast-on connection line (0.3 m) at the magnetic sensor. Even more performance, e.g. extension cables are offered for use in a cable management chain. ) | ‒ | ||
Bending cycles (Technical data only for the cast-on connection line (0.3 m) at the magnetic sensor. Even more performance, e.g. extension cables are offered for use in a cable management chain. ) | ‒ | ||
Maximum permissible acceleration (Technical data only for the cast-on connection line (0.3 m) at the magnetic sensor. Even more performance, e.g. extension cables are offered for use in a cable management chain. ) | ‒ | ||
Protection type | IP66 | ||
Certifications and approvals | ‒ |
Stock | Ask for quotation |
---|---|
Part number | R347602303 |
Manufacturer | REXROTH |
Quantity | Unit Price |
---|---|
1+ | $175.57 |