Specifications

Width Weight Mounting Position
595 mm 275,000g vertical
industrial valves dt8p1-06-65-11-in13
product dt8p1 : please refer to product catalog/contact csr for more details
number of phases (input) 3
10.10 temperature rise the panel builder is responsible for the temperature rise calculation. eaton will provide heat dissipation data for the devices.
ambient operating temperature at 150% overload - min -10 °c
rated frequency - max 66 hz
number of hw-interfaces (other) 1
10.2.3.2 verification of resistance of insulating materials to normal heat meets the product standard's requirements.
rated frequency - min 45 hz
rated operational power at 380/400 v, 50 hz, 3-phase 160 kw
number of outputs (analog) 1
relative symmetric net voltage tolerance 10 %
heat dissipation per pole, current-dependent pvid 0 w
10.9.4 testing of enclosures made of insulating material is the panel builder's responsibility.
Mounting position vertical
rated control supply voltage 10 v dc (us, max. 10 ma)
voltage rating - max 480 vac
static heat dissipation, non-current-dependent pvs 0 w
climatic proofing < 95 % relative humidity, no condensation, no corrosion, no dripping water
number of relay outputs 2 (parameterizable, n/o, 8 a (24 v dc) / 8 a (250 v ac) / 0,4 a (125 v dc))
10.8 connections for external conductors is the panel builder's responsibility.
number of hw-interfaces (rs-485) 1
10.12 electromagnetic compatibility is the panel builder's responsibility. the specifications for the switchgear must be observed.
number of phases (output) 3
application in domestic and commercial area permitted yes
10.2.4 resistance to ultra-violet (uv) radiation meets the product standard's requirements.
10.2.2 corrosion resistance meets the product standard's requirements.
converter type u converter
output at linear load at rated output voltage - max 160 kw
ambient storage temperature - max 70 °c
10.9.2 power-frequency electric strength is the panel builder's responsibility.
rated operational current (ie) at 150% overload 300 a
rated control voltage (uc) 24 v dc (external, max. 250 ma)
radio interference class c2, c3: depending on the motor cable length, the connected load, and ambient conditions. external radio interference suppression filters (optional) may be necessary.
assigned motor power at 460/480 v, 60 hz, 3-phase, 110 % overload 300 hp
10.2.6 mechanical impact does not apply, since the entire switchgear needs to be evaluated.
10.6 incorporation of switching devices and components does not apply, since the entire switchgear needs to be evaluated.
heat dissipation details operation (with 150 % overload)
output voltage (u2) 500 v ac, 3-phase
400 v ac, 3-phase
480 v ac, 3-phase
communication interface bacnet/ip, optional
canopen®, optional
profibus-dp
lonworks, optional
devicenet, optional
modbus-tcp, optional
bacnet ms/tp, optional
ethercat, optional
ethernet ip, optional
modbus-rtu, optional
profinet, optional
ambient operating temperature - max 50 °c
output frequency - min 0 hz
mains voltage - min 380 v
10.2.3.1 verification of thermal stability of enclosures meets the product standard's requirements.
output at quadratic load at rated output voltage - max 200 kw
rated operational voltage 500 v ac, 3-phase
480 v ac, 3-phase
400 v ac, 3-phase
rated operational current for specified heat dissipation (in) 300 a
assigned motor current im at 440 - 480 v, 60 hz, 150% overload 302 a
Product weight 275 kg
product height 2020 mm
ean 4015081232819
altitude max. 1000 m
max. 3000 m
above 1000 m with 1 % performance reduction per 100 m
assigned motor current im at 400 v, 50 hz, 150% overload 279 a
relative symmetric net frequency tolerance 10 %
10.7 internal electrical circuits and connections is the panel builder's responsibility.
rated operational current (ie) at 110% overload 385 a
10.2.3.3 resist. of insul. mat. to abnormal heat/fire by internal elect. effects meets the product standard's requirements.
number of outputs (digital) 1
operating mode optional: vector control with feedback (clv)
u/f control
sensorless vector control (slv)
suitable for branch circuits, (ul/csa)
equipment heat dissipation, current-dependent pvid 4000 w
resolution 0.01 hz (frequency resolution, setpoint value)
electromagnetic compatibility 1st and 2nd environments (according to en 61800-3)
10.13 mechanical function the device meets the requirements, provided the information in the instruction leaflet (il) is observed.
10.5 protection against electric shock does not apply, since the entire switchgear needs to be evaluated.
number of inputs (digital) 6
10.9.3 impulse withstand voltage is the panel builder's responsibility.
connection to smartwire-dt no
application in industrial area permitted yes
protection finger and back-of-hand proof, protection against direct contact (bgv a3, vbg4)
system configuration type ac supply systems with earthed center point
10.2.5 lifting does not apply, since the entire switchgear needs to be evaluated.
assigned motor current im at 440/480 v, 60 hz, 110% overload 361 a
number of inputs (analog) 2
10.2.7 inscriptions meets the product standard's requirements.
supply frequency 50/60 hz
frame size fr10
assigned motor current im at 400 v, 50 hz, 110% overload 349 a
functions 4-quadrant operation possible
Degree of protection nema 1
ip21
Protocol other bus systems
tcp/ip
devicenet
data-highway
profibus
can
lon
assigned motor power at 460/480 v, 60 hz, 3-phase 250 hp
heat dissipation capacity pdiss 0 w
product category variable frequency drives
10.3 degree of protection of assemblies does not apply, since the entire switchgear needs to be evaluated.
nominal output current i2n 385 a
ambient operating temperature - min -10 °c
switching frequency 3.6 khz, 1 - 6 khz adjustable, fpwm, power section, main circuit
output frequency - max 320 hz
rated operational power at 380/400 v, 50 hz, 3-phase, 110% overload 200 kw
ambient operating temperature at 150% overload - max 50 °c
fitted with: control unit
dc link choke
pc connection
radio interference suppression filter
internal dc link
igbt inverter
oled display
ambient storage temperature - min -40 °c
output voltage - max 500 v
10.4 clearances and creepage distances meets the product standard's requirements.
10.11 short-circuit rating is the panel builder's responsibility. the specifications for the switchgear must be observed.
mains voltage - max 500 v
certifications cul
iec/en61800-5
ul
ul category control no.: nmms, nmms2, nmms7. nmms8
safety: en 61800-5-1: 2003
iec/en 61800-3
ul file no.: e134360
ce
certified by ul for use in canada
csa class no.: 3211-06
rcm
iec/en61800-3
specification for general requirements: iec/en 61800-2
csa-c22.2 no. 14
dnv
rohs, iso 9001
ul report applies to both us and canada
ul 508c
product width 595 mm
product length/depth 602 mm